http://WWW.DELCOTLTD.COM
DELCOTENG 599c16d946ec470afcd65856 False 774 52
OK
background image not found
Found results for
'transient load changes'
ESD 2210 INR   0 INR  0
-NaN%

ESD 2210

ESD2210 SERIES (CE)- ANALOG GOVERNORS The ESD2210 Series speed control unit is an all- electronic device designed to control engine speed with fast and precise response to transient load changes. This closed loop control, when connected to a proportional electric actuator and supplied with a magnetic speed sensor signal, will control a wide variety of engines in an isochronous or droop mode. It is designed for high reliability and it's hard potted to withstand the engine environment.

INR 0 INR 0

Availability:True

Pay mode:COD only

view details
Acoustic Enclosure INR   45000 INR  45000
-0%

Acoustic Enclosure

The acoustic enclosure is made of 1.6/ 2 mm thick CRCA sheets and structural/ sheet metal base frame painted in Munsel green shade. The walls of the enclosure are insulated with fire retardant foam so as to comply with the 75 dBA at 1mtr sound levels specified by Ministry of Environment & Forest.. The acoustic enclosure has the following features: Specially designed to meet stringent MOEF/ CPCB norms of 75 dBA @ 1mtr at 75% load under free field conditions upto 1000 kvA Designed to have optimum serviceability Air inlet louvers specially designed to operate at rated load even at 50 deg. C enclosure temp. Made on special purpose CNC machines for consistency in quality and workmanship Powder coated for long lasting service life and superior finish With UV resistant powder coating, can withstand extreme environments Use of stainless steel hardware Insulation material meets exacting IS 8183 specs for better sound attenuation For gensets of 1010 kvA & above special A/E can also be provided for Outdoor installation with insertion less of 25 dba For Indoor installations acoustic treatments for walls, roofs with modular build pa

INR 45000 INR 45000

Availability:True

Pay mode:COD only

view details
AMF Panel Specification 15 KVA INR   35000 INR  35000
-0%

AMF Panel Specification 15 KVA

SPECIFICATION FOR STANDARD AMF PANEL 15 KVA Cubicle type, base mounting control panel with hinged doors, undrilled bottom gland plate, AL. Bus Bar and accommodating the following: SWITCH GEARS: 32A, 4 Pole Contactor for ALTERNATOR with Thermal O/L relay 32A, 4 Pole Contactor for MAINS (OPTIONAL) BACK-UP PROTECTION: MCB for short circuit protection MICROPROCESSOR BASED AMF MODULE INCORPORATING: Functions: Supply Failure Timer Restoration Timer 3 Impulse automatic engine Start / Stop logic & engine fails to start lockout Mains / Generator Voltage & Frequency Sensing. Multifunctional Meter with Scrolling Readings for Water Temperature/ Oil Pressure Voltage / Ampere/ Frequency / kW / kVA Running-hour counter Electronic kWH meter (Counter Display) Current Transformers Indications (LED): DG ON, Load on DG Mains ON, Load on Mains, Battery Charger ON Push Buttons (AMF MODULE BY PASS MODE) Engine START / STOP ( Provided on Engine Controller ) Generator Contactor CLOSE / TRIP Mains Contactor CLOSE / TRIP (If provided) Fault ACCEPT / RESET BATTERY CHARGER: SMPS Based Unit with inbuilt Auto/Manual & Float/Boost Facility DC Voltmeter & Ammeter (Separate) PLHO / 0712/RKS/ASN

INR 35000 INR 35000

Availability:True

Pay mode:COD only

view details
Cummins Radiator Core INR   12500 INR  12500
-0%

Cummins Radiator Core

Our professionals are involved in supplying an extensive range of Cores for Gensets, which is widely used in heavy industries automotive to transfer high rate of heat. We have used optimum quality raw material, procured from authentic market vendors. Moreover, also known as pranav radiators, these products are appreciated for their optimum performance under aggressive, transient and low speed conditions.

INR 12500 INR 12500

Availability:True

Pay mode:COD only

view details
SX440 AVR Stamford (Original) INR   8500 INR  8500
-0%

SX440 AVR Stamford (Original)

=========> If any enquiries :- Whatsapp :- +91-9380-95-66-77 /------or----->/ +91-7667-22-22-40 /----------> E-mail :- admin@delcot.in ========= > General Description / Specifications SX440 is a half-wave phase-controlled thyristor type Automatic Voltage Regulator (AVR) and forms part of the excitation system for a brush-less generator. In addition to regulating the generator voltage, the AVR circuitry includes under-speed and sensing loss protection features. Excitation power is derived directly from the generator terminals. Positive voltage build up from residual levels is ensured by the use of efficient semiconductors in the power circuitry of the AVR.The AVR is linked with the main stator windings and the exciter field windings to provide closed loop control of the output voltage with load regulation of +/- 1.5%. In addition to being powered from the main stator, the AVR also derives a sample voltage from the output windings for voltage control purposes. In response to this sample voltage, the AVR controls the power fed to the exciter field, and hence the main field, to maintain the machine output voltage within the specified limits, compensating for load, speed, temperature and power factor of the generator. A frequency measuring circuit continually monitors the generator output and provides output under-speed protection of the excitation system, by reducing the output voltage proportionally with speed below a pre-settable threshold. A manual adjustment is provided for factory setting of the under frequency roll off point, (UFRO).This can easily be changed to 50 or 60 Hz in the field by pushon link selection. Provision is made for the connection of a remote voltage trimmer, allowing the user fine control of the generator's output. General Characteristics�� INPUT ��� > Voltage Jumper selectable 95-132V ac or 190-264V ac ��� > Frequency 50-60 Hz nominal ��� > Phase 1 OUTPUT ��� > Voltage max 90V dc at 207V ac input ��� > Current continuous 4 A dc Intermittent 6 A for 10 secs ��� > Resistance 15 ohms minimum REGULATION ��� > +/- 1.5% THERMAL DRIFT ��� > 0.05% per deg. C change in AVR ambient TYPICAL SYSTEM RESPONSE ��� > AVR response 20 ms ��� > Filed current to 90% 80 ms ��� > Machine Volts to 97% 300 ms EXTERNAL VOLTAGE ADJUSTMENT ��� > +/-10% with 1 k ohm 1 watt trimmer UNDER FREQUENCY PROTECTION ��� > Set point 95% Hz ��� > Slope 170% down to 30 Hz UNIT POWER DISSIPATION ��� > 10 watts maximum BUILD UP VOLTAGE ��� > 4 Volts @ AVR terminals ENVIRONMENTAL ��� > Vibration 20-100 Hz 50mm/sec ��� > 100Hz � 2kHz 3.3g ��� > Operating temperature -40 to +70�C ��� > Relative Humidity 0-70�C 95% (see note 5) ��� > Storage temperature -55 to +80�C NOTES 1. With 4% engine governing 2. After 10 minutes. 3. Applies to Mod status F onwards. Generator de-rate may apply. Check with factory. 4. Factory set, semi-sealed, jumper selectable 5. Non condensing. Standard Applications Stamford Alternator BC16, BC18, UC22,�UC27 InGENERAL POWERwe�understand�the urgency of your�requirements for emergency and back up generators, and we have committed by establishing automatic voltage regulator stock of 500+ units in Miami Florida generator stock of 300+ units in Miami Florida currently serving: Pay Mode Terms: L/C (Letter of Credit),T/T (Bank Transfer),D/P,D/A,Other =========> If any enquiries :- Whatsapp :- 9380-95-66-77 /------or----->/ 7667-22-22-40 /----------> E-mail :- admin@delcot.in

INR 8500 INR 8500

Availability:True

Pay mode:COD only

view details
1
false